计算机视觉硬件工业相机 镜头 机器视觉光源 采集卡 线材 配件 网络和外围设备计算机视觉软件pylon Camera Software Suite pylon vTools VisualApplets 其他软件产品线嵌入式视觉产品线 医疗和生命科学产品线 CoaXPress产品线 5GigE产品线 3D产品线面阵相机Basler ace 2 短波红外相机 Basler ace Basler MED ace Basler boost Basler beat Basler dart Basler pulseBasler aceace lite线阵相机Basler racerpylon Camera Software Suitepylon vTools pylon开源项目 pylon-data-faq pylon驱动程序和GenTL pylon SDKs pylon Viewer
- 选型工具
- 解决方案
- 下载中心
- 品牌中心
- 销售与支持
-
Vision Campus
相机技术Sony IMX CMOS芯片系列型号比较 为什么要对相机进行色彩校准? 专家教您如何为视觉系统找到合适的镜头 适用于嵌入式视觉系统的五大专家级技巧 什么是多光谱成像? CMOS相机比较 图像处理过程中的色彩 处理板 什么是图像处理 图像处理中的3D技术 什么是嵌入式视觉? 为何选择CMOS图像芯片? 什么是ToF (Time-of-Flight)? 什么是成像质量? 相机尺寸 数字相机的工作原理是什么? 芯片技术:CMOS与CCD的对比 实时性 NIR: 即使在弱光条件也可以呈现清晰图像 高灵敏度图像处理相机 Time-of-Flight versus Stereovision显示更多收起接口和标准千兆网(GigE) 什么是CoaXPress? 配备GigE 2.0的多相机系统 System Setup with CoaXPress 2.0 USB 3.0和USB3 Vision Camera Link 哪一款接口适合嵌入式视觉? GenICam标准
- 公司概况
Can you tell me about the precision of the quartz oscillators used in Basler cameras?
If you happen to need to synchronize times, for example, the image timestamp from multiple cameras or the image timestamp with a PC time, you should consider the drift of the quartz oscillator used in Basler cameras (as well the drift of the PC quartz oscillator).
Every quartz oscillator has a time drift, and this drift is influenced by its surrounding temperature. The oscillator used in Basler cameras has a precision of about ± 30 ppm (parts per million) at a 25°C environmental temperature. The precision of the quartz in ace U GigE series cameras is about ±50ppm.
In the worst case, i.e., for the temperature range from 0 to 50°C, it has a precision of about ±100 ppm. That explains why we can assume the precision at 25°C to be the relative precision at a constant temperature.
So, for example, 14 hours are made up of 50400 seconds or 5.04 x 10^7 milliseconds.
For ±30 ppm, you would have a drift of about ±1512 ms (or about 1.5 s) per 14 hours.
For ±50ppm, you would have a drift of about ±2520 ms (about 2.5s) per 14 hours.
For ±100 ppm you would have ±5040 ms (about 5 s) per 14 hours.
Note that these values are related to the absolute frequency drift, so the drift at a relatively constant temperature should be significantly smaller.